❌

Reading view

PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping

arXiv:2607.20136v2 Announce Type: replace-cross Abstract: Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations. Existing SVR methods are optimized and validated only for clinical-range echo times (TEs), limiting their use at non-clinical TEs and making them incompatible with quantitative T2 mapping, a protocol- and center-independent biomarker of fetal brain maturation requiring HR reconstructions across multiple TEs. We present PRIME-SVR, the first implicit neural representation (INR) framework for joint HR reconstruction from multi-echo MRI. A single fully connected network models a continuous function from spatial coordinates to signal intensities across TEs, while a second network estimates slice-specific acquisition degradations. Cross-TE coherence is enforced via a Bloch equation-derived regularization penalizing deviations from expected T2 decay, with adaptive weighting that strengthens coupling for degraded stacks. The method is fully self-supervised. We validate PRIME-SVR on 39 in vivo fetal acquisitions (13 subjects x 3 TEs) from two centers, two vendors, and two field strengths (1.5 T and 0.55 T). Compared to state-of-the-art SVR, PRIME-SVR improves reconstruction sharpness by 47%, anatomical accuracy by 30%, and cross-TE structural consistency by 14%. It enables reconstruction at late TEs previously inaccessible to SVR, yielding the first 0.8 mm isotropic T2 maps at 0.55 T and the first T2 maps derived from INR-based SVR. PRIME-SVR also accelerates quantitative imaging by reducing the data needed for multi-TE reconstruction, cutting acquisition from 15 to 10 minutes while keeping T2 accuracy within 1.7% in white and deep gray matter, or to 5 minutes with a mean T2 error of 2.3% for high-quality acquisitions.
  •  

Echo2ECG: Enhancing ECG Representations with Cardiac Morphology from Multi-View Echos

arXiv:2603.08505v1 Announce Type: cross Abstract: Electrocardiography (ECG) is a low-cost, widely used modality for diagnosing electrical abnormalities like atrial fibrillation by capturing the heart's electrical activity. However, it cannot directly measure cardiac morphological phenotypes, such as left ventricular ejection fraction (LVEF), which typically require echocardiography (Echo). Predicting these phenotypes from ECG would enable early, accessible health screening. Existing self-supervised methods suffer from a representational mismatch by aligning ECGs to single-view Echos, which only capture local, spatially restricted anatomical snapshots. To address this, we propose Echo2ECG, a multimodal self-supervised learning framework that enriches ECG representations with the heart's morphological structure captured in multi-view Echos. We evaluate Echo2ECG as an ECG feature extractor on two clinically relevant tasks that fundamentally require morphological information: (1) classification of structural cardiac phenotypes across three datasets, and (2) retrieval of Echo studies with similar morphological characteristics using ECG queries. Our extracted ECG representations consistently outperform those of state-of-the-art unimodal and multimodal baselines across both tasks, despite being 18x smaller than the largest baseline. These results demonstrate that Echo2ECG is a robust, powerful ECG feature extractor. Our code is accessible at https://github.com/michelleespranita/Echo2ECG.
  •  

VariViT: A Vision Transformer for Variable Image Sizes

arXiv:2602.14615v1 Announce Type: cross Abstract: Vision Transformers (ViTs) have emerged as the state-of-the-art architecture in representation learning, leveraging self-attention mechanisms to excel in various tasks. ViTs split images into fixed-size patches, constraining them to a predefined size and necessitating pre-processing steps like resizing, padding, or cropping. This poses challenges in medical imaging, particularly with irregularly shaped structures like tumors. A fixed bounding box crop size produces input images with highly variable foreground-to-background ratios. Resizing medical images can degrade information and introduce artefacts, impacting diagnosis. Hence, tailoring variable-sized crops to regions of interest can enhance feature representation capabilities. Moreover, large images are computationally expensive, and smaller sizes risk information loss, presenting a computation-accuracy tradeoff. We propose VariViT, an improved ViT model crafted to handle variable image sizes while maintaining a consistent patch size. VariViT employs a novel positional embedding resizing scheme for a variable number of patches. We also implement a new batching strategy within VariViT to reduce computational complexity, resulting in faster training and inference times. In our evaluations on two 3D brain MRI datasets, VariViT surpasses vanilla ViTs and ResNet in glioma genotype prediction and brain tumor classification. It achieves F1-scores of 75.5% and 76.3%, respectively, learning more discriminative features. Our proposed batching strategy reduces computation time by up to 30% compared to conventional architectures. These findings underscore the efficacy of VariViT in image representation learning. Our code can be found here: https://github.com/Aswathi-Varma/varivit
  •  
❌