❌

Reading view

Performance of AI-Based Screening Tools for Obstructive Sleep Apnea Across Apnea-Hypopnea Index Thresholds: Systematic Review and Meta-Analysis

Background: Obstructive sleep apnea (OSA) is highly prevalent but remains substantially underdiagnosed. Polysomnography (PSG) is the reference standard, but its cost and limited availability constrain large-scale case identification. AI-based screening tools may support risk stratification and referral prioritization, but their diagnostic accuracy across apnea-hypopnea index (AHI) thresholds remains uncertain. Objective: This review aimed to systematically evaluate the diagnostic accuracy of AI-based OSA screening tools at AHI thresholds of β‰₯5, β‰₯15, and β‰₯30 events/hour, with emphasis on models using non-PSG–derived inputs. Methods: PubMed, Embase, Scopus, and Web of Science were searched for studies published from January 1, 2016, to May 3, 2026. Eligible studies included adults evaluated for suspected OSA or recruited from population-based cohorts, assessed AI-based models intended or interpretable for OSA screening, risk prediction, or screening-oriented severity classification, used PSG as the reference standard, and reported sufficient data to construct or reconstruct 2Γ—2 contingency tables. Diagnostic accuracy was synthesized separately by AHI threshold and input source using bivariate random-effects models, with 95% CIs and prediction intervals (PIs). Risk of bias and certainty of evidence were assessed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) and GRADE (Grading of Recommendations Assessment, Development, and Evaluation), respectively. Results: A total of 60 studies were included, of which 47 contributed data to the meta-analysis. At AHI thresholds of β‰₯5, β‰₯15, and β‰₯30 events/hour, pooled sensitivities were 0.94 (95% CI 0.92‐0.96; 95% PI 0.71‐0.99), 0.87 (95% CI 0.84‐0.89; 95% PI 0.66‐0.96), and 0.83 (95% CI 0.79‐0.87; 95% PI 0.61‐0.94), respectively; the corresponding specificities were 0.77 (95% CI 0.69‐0.84; 95% PI 0.30‐0.96), 0.81 (95% CI 0.75‐0.85; 95% PI 0.39‐0.96), and 0.91 (95% CI 0.87‐0.94; 95% PI 0.55‐0.99), respectively. The corresponding areas under the summary receiver operating characteristic curves were 0.943, 0.907, and 0.920. For non-PSG–derived tools, sensitivities were 0.92, 0.85, and 0.81, and specificities were 0.70, 0.74, and 0.85 at the 3 thresholds, respectively. For PSG-derived models, sensitivities were 0.96, 0.90, and 0.85, and specificities were 0.82, 0.88, and 0.96, respectively. Exploratory subgroup analyses suggested performance variation across selected study and model characteristics, including region, algorithmic framework, data source, and validation method. Conclusions: AI-based tools showed generally favorable screening performance for OSA across clinically relevant AHI thresholds, although wide PIs suggest variable performance across future comparable populations and settings. By synthesizing diagnostic accuracy across 3 AHI thresholds and distinguishing non-PSG–derived from PSG-derived models, this review extends previous broad or modality-specific reviews and offers a clinically interpretable, pathway-specific basis for linking model performance to intended use. The findings may clarify potential roles for non-PSG–derived tools in front-end screening and referral prioritization and for PSG-derived models in reduced-channel assessment and sleep-laboratory workflow support. Given substantial heterogeneity, limited external validation, and low or very low certainty of evidence, prospective validation is needed before routine implementation.
  •  

From Static Spectra to Operando Infrared Dynamics: Physics Informed Flow Modeling and a Benchmark

arXiv:2602.18551v1 Announce Type: cross Abstract: The Solid Electrolyte Interphase (SEI) is critical to the performance of lithium-ion batteries, yet its analysis via Operando Infrared (IR) spectroscopy remains experimentally complex and expensive, which limits its accessibility for standard research facilities. To overcome this bottleneck, we formulate a novel task, Operando IR Prediction, which aims to forecast the time-resolved evolution of spectral ``fingerprints'' from a single static spectrum. To facilitate this, we introduce OpIRSpec-7K, the first large-scale operando dataset comprising 7,118 high-quality samples across 10 distinct battery systems, alongside OpIRBench, a comprehensive evaluation benchmark with carefully designed protocols. Addressing the limitations of standard spectrum, video, and sequence models in capturing voltage-driven chemical dynamics and complex composition, we propose Aligned Bi-stream Chemical Constraint (ABCC), an end-to-end physics-aware framework. It reformulates MeanFlow and introduces a novel Chemical Flow to explicitly model reaction trajectories, employs a two-stream disentanglement mechanism for solvent-SEI separation, and enforces physics and spectrum constraints such as mass conservation and peak shifts. ABCC significantly outperforms state-of-the-art static, sequential, and generative baselines. ABCC even generalizes to unseen systems and enables interpretable downstream recovery of SEI formation pathways, supporting AI-driven electrochemical discovery.
  •  
❌