❌

Reading view

MacTok: Robust Continuous Tokenization for Image Generation

arXiv:2603.29634v1 Announce Type: cross Abstract: Continuous image tokenizers enable efficient visual generation, and those based on variational frameworks can learn smooth, structured latent representations through KL regularization. Yet this often leads to posterior collapse when using fewer tokens, where the encoder fails to encode informative features into the compressed latent space. To address this, we introduce \textbf{MacTok}, a \textbf{M}asked \textbf{A}ugmenting 1D \textbf{C}ontinuous \textbf{Tok}enizer that leverages image masking and representation alignment to prevent collapse while learning compact and robust representations. MacTok applies both random masking to regularize latent learning and DINO-guided semantic masking to emphasize informative regions in images, forcing the model to encode robust semantics from incomplete visual evidence. Combined with global and local representation alignment, MacTok preserves rich discriminative information in a highly compressed 1D latent space, requiring only 64 or 128 tokens. On ImageNet, MacTok achieves a competitive gFID of 1.44 at 256$\times$256 and a state-of-the-art 1.52 at 512$\times$512 with SiT-XL, while reducing token usage by up to 64$\times$. These results confirm that masking and semantic guidance together prevent posterior collapse and achieve efficient, high-fidelity tokenization.
  •  

To Reason or Not to: Selective Chain-of-Thought in Medical Question Answering

arXiv:2602.20130v1 Announce Type: cross Abstract: Objective: To improve the efficiency of medical question answering (MedQA) with large language models (LLMs) by avoiding unnecessary reasoning while maintaining accuracy. Methods: We propose Selective Chain-of-Thought (Selective CoT), an inference-time strategy that first predicts whether a question requires reasoning and generates a rationale only when needed. Two open-source LLMs (Llama-3.1-8B and Qwen-2.5-7B) were evaluated on four biomedical QA benchmarks-HeadQA, MedQA-USMLE, MedMCQA, and PubMedQA. Metrics included accuracy, total generated tokens, and inference time. Results: Selective CoT reduced inference time by 13-45% and token usage by 8-47% with minimal accuracy loss ($\leq$4\%). In some model-task pairs, it achieved both higher accuracy and greater efficiency than standard CoT. Compared with fixed-length CoT, Selective CoT reached similar or superior accuracy at substantially lower computational cost. Discussion: Selective CoT dynamically balances reasoning depth and efficiency by invoking explicit reasoning only when beneficial, reducing redundancy on recall-type questions while preserving interpretability. Conclusion: Selective CoT provides a simple, model-agnostic, and cost-effective approach for medical QA, aligning reasoning effort with question complexity to enhance real-world deployability of LLM-based clinical systems.
  •  
❌